Providing precise measurement of Chloride in numerous sample types: the M926S Chloride Analyser is intended for general laboratory use and calibrated to give results in mmol/l Chloride. The Select Button allows the Operator to choose to work with 20µl or 100µl sample volumes. The M926S is widely used for Chloride determination in Sweat samples
Highlights:
• Principle coulometric method of operation is very robust, tried and tested
• Analyser is ergonomically designed, easy to use and maintain
• Sherwood Chloride Analyser Buffer enables outstanding performance for precision
• Low cost per test
• Low after test costs (reagent disposal)
Further information about the product: The M926S Chloride Analyser method of operation is based on a coulometric titration wherein the reagent (Silver ions) is precisely and quantitatively generated at the time of analysis by passing a constant current between electrodes. The endpoint is determined when excess Silver ions cause a change in conductivity; detected by the detector electrodes.
Measurement of Salt (Sodium Chloride) in the Food and Dairy Industry is a universal requirement. Instrumental endpoint detection and the option to read Salt concentration directly have made the M926 Chloride Analyser the instrument of choice for many food manufacturers and analysts worldwide. Salt and salinity also represent serious contamination in many industrial processes. The sensitivity of the coulometric method enables ppm range measurement in boiler feed water; polymer washes; borehole slurries as well and soil salinity studies. The M926 Chloride Analyser is intended for general laboratory use and is calibrated in ppm (mg/l) Chloride. The Select Button offers the immediate conversion of Chloride content into mg% Salt (Sodium Chloride) of the original sample*.
* assumes a ratio of 1g of sample to 100ml diluent
Highlights:
• Principle coulometric method of operation is very robust, tried and tested
• Analyser is ergonomically designed, easy to use and maintain
• Sherwood Scientific Chloride Analyser Buffer enables outstanding performance for precision
• Low cost per test
• Low after test costs (reagent disposal)
Further information about the product: The M926 method is based on a coulometric titration wherein the reagent (Silver ions) is precisely and quantitatively generated at the time of analysis by passing a constant current between electrodes. The endpoint is determined when excess Silver ions cause a change in conductivity; detected by the detector electrodes.