Digital Polarimeters

ADS435-F100 Series Saccharimeter

With flow and ATC, 589nm, 100mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the Sodium (589nm) wavelength.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS435 Series Saccharimeter

ATC, 589nm, 200mm Glass

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the Sodium (589nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS435-F200 Series Saccharimeter

With flow and ATC, 589nm, 200mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the Sodium (589nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS438 Series Saccharimeter

ATC, NIR, 200mm Glass

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the NIR (850nm) wavelength.
• ATC or Patented XPC Peltier ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS438-F100 Series Saccharimeter

With flow and ATC, NIR, 100mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the NIR (850nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS438-F200 Series Saccharimeter

With flow and ATC, NIR, 200mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the NIR (850nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS455 Series Saccharimeter

XPC Peltier, 589nm, 200mm Metal

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the Sodium (589nm) wavelength.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS455-F100 Series Saccharimeter

With flow and XPC Peltier, 589nm, 100mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the Sodium (589nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS455-F200 Series Saccharimeter

With flow and XPC Peltier, 589nm, 200mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the Sodium (589nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS458 Series Saccharimeter

XPC Peltier, NIR, 200mm Metal

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the NIR (850nm) wavelength.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS458-F100 Series Saccharimeter

With flow and XPC Peltier, NIR, 100mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the NIR (850nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


ADS458-F200 Series Saccharimeter

With flow and XPC Peltier, NIR, 200mm Funnel

The ADS400 Series Saccharimeter is a purpose built polarimeter that displays results in the ISS (°Z) scale. This series of Bellingham + Stanley instruments has been primarily designed for busy sugar laboratories, factories and tare houses. This ADS400 Series Saccharimeter measures in the NIR (850nm) wavelength and comes with funnel flow technology.
• ATC or Patented XPC Peltier
• ICUMSA and Tropical Scale ATC
• Funnel flow or standard tube packages
• High definition 4“ full colour display
• Continuous or single shot readings
ADS400 Series Saccharimeters can be purchased with or without XPC Technology – Xylem’s patented Peltier temperature control system.
The ADS400 Series Saccharimeters are designed to operate in isolation but work best when connected to an RFM Refractometer to create a complete Purity system that facilitates accurate purity readings.


Polarimeter ADP450

Single Wavelength with Temperature Control

Single wavelength polarimeter with XPC temperature control and low maintenance LED light source. Suitable for sugar, food, chemical and pharmaceutical industries.
• XPC Temperature Control
•Up to 200mm tube length
•Standard ICUMSA tubes
•Continuous or single-shot readings
•Conforms to USP/EP/BP/JP (@589nm)
The ADP400 polarimeters are available with or without XPC – Xylem’s patented internal Peltier temperature control system. Both models use standard ICUMSA polarimeter tubes with a maximum length of 200mm.
These polarimeters contain proven optics, pioneered by Bellingham + Stanley, featuring “no maintenance” yellow LED and interference filter. Combined with a photodiode detector these technologies allow for the reading of samples of up to 3.0 OD at the commonly used sodium (589nm) wavelength. ADP400 polarimeters feature angular and sugar scales (ISS) and can be programmed with user scales as well as industry standard methods for displaying invert sugar, inversion (A-B) or when applying other factors such as tube length and concentration, Specific Rotation (or concentration when entering specific rotation). This flexibility makes them ideal for use within laboratories where compliance with Pharmacopoeia is required.
ADP400 Series polarimeters have a resolution of 0.001 angular degrees (°A) and are capable of reading to an accuracy of ±0.010 °A. When working under laboratory controlled conditions, ADP400 polarimeters also offer excellent reproducibility of up to 0.002 °A.


Polarimeter ADP600 Series

Single/Dual/Multiple Wavelength with Temperature Control

Bellingham + Stanley Single/Dual/Multiple Wavelength Polarimeter ADP600 Series with temperature control are designed for measuring optical rotation. They are especially suited for use by scientists wishing to measure chiral compounds and other optically active substances in the chemical, pharmaceutical and food sectors as well as for use in academic research.
• XPC Peltier temperature controlled
• Four decimal place resolution
• Conforms to USP/EP/BP/JP
• RFID user clearance
• High Definition touchscreen
Digital Polarimeters with Temperature Control
The ADP600 Series of polarimeters are available as multiple, dual, or single wavelength models, and with the ability to measure optical rotation to 4 decimal places across the visible spectrum as well as in the highly sensitive ultra-violet region. The series is split between 325, 365, 405, 436, 546, 589 & 633nm wavelengths depending on the model. Other wavelengths available on request, subject to interference filter availability.
The line of digital polarimeters features Xylem’s XPC temperature control technology. XPC technology replaces air temperature systems seen in previous models, providing for faster temperature stabilisation that is more representative of the sample than the air surrounding it.
The wide range of measuring capabilities, excellent temperature stability and high precision makes the ADP600 Series an excellent choice for laboratories within chemical, pharmaceutical and food sectors.
ADP600 Series Polarimeters accept standard size (30mm collar) XPC or special low volume leur taper polarimeter tubes facilitating measurement across optical path lengths between 5 and 200mm with tube diameters from 5 to 8mm being readable. Optional lids may be easily fitted to the ADP600 Series Polarimeters, facilitating sample tube entry and exit.


Polarimeter ADP430

Single Wavelength

Single wavelength polarimeter with low maintenance LED light source. Suitable for sugar, food, chemical and pharmaceutical industries.
• Can be used with waterbath
• Up to 200mm tube length
• Standard ICUMSA tubes
• Continuous or single-shot readings
• Conforms to USP/EP/BP/JP (@589nm)
The ADP400 polarimeters are available with or without XPC – Xylem’s patented internal Peltier temperature control system. Both models use standard ICUMSA polarimeter tubes with a maximum length of 200mm.
These polarimeters contain proven optics, pioneered by Bellingham + Stanley, featuring “no maintenance” yellow LED and interference filter. Combined with a photodiode detector these technologies allow for the reading of samples of up to 3.0 OD at the commonly used sodium (589nm) wavelength. ADP400 polarimeters feature angular and sugar scales (ISS) and can be programmed with user scales as well as industry standard methods for displaying invert sugar, inversion (A-B) or when applying other factors such as tube length and concentration, Specific Rotation (or concentration when entering specific rotation). This flexibility makes them ideal for use within laboratories where compliance with Pharmacopoeia is required.
ADP400 Series polarimeters have a resolution of 0.001 angular degrees (°A) and are capable of reading to an accuracy of ±0.010 °A. When working under laboratory controlled conditions, ADP400 polarimeters also offer excellent reproducibility of up to 0.002 °A.





Contact

  • 21 Vasco Boulevard
  • Goodwood
  • 7460
  • South Africa
  • Email:
    This email address is being protected from spambots. You need JavaScript enabled to view it.

  • Branch Contact Details:
    Click Here

Follow us

We accept SnapScan payments
from COD clients